Page view 15
M A R Q U I S S P A S
®
OWNER’S MANUAL
SPIRIT™
# Component Identification Quantity
1 HK™8 Neck Jets 2
2 HK™12 Jets 12
3 HK™16 Jets 1
4 HK™40 Jets 4
5 Light* 1
7 Suction Fitting 1
8 Floor Drain 1
9 Jet Selector 1
10 Neck Jet Valve 1
11 Bather’s Control Panel 1
12 Filter Canisters 2
13 Spa Frog®* 1
14 Spa Frog® Return Fitting* 1
15 Ozone Injector Fitting* 1
16 Waterfall Feature* 1
17 Waterfall Valve* 1
19 Constellation* 12
20 Cushioned Headrests* 2
21 Adagio™ Speakers* 2
22 Water Feature* 1
TROUBLESHOOTING GUIDE
PLEASE NOTE: The following corrective actions may be performed by the spa
owner. If the trouble cannot be corrected in the steps below, please contact your
authorized Marquis spa dealer for service. (Improper servicing by an unauthorized
service provider or spa owner could result in damage not covered by the warranty and
could cause serious injury.)
EQUIPMENT WILL NOT OPERATE
Check the control panel LCD window for diagnostic code.
Check the circuit breaker on the main circuit panel.
Check the condition of the power cord.
INADEQUATE JET ACTION
Be sure the shut-off valves are completely open.
Open the jets by turning the jet face to allow for maximum water flow.
Check that the air control valve is open (rotate lever counterclockwise).
Check for obstruction or restrictions at suction guard(s) or filters, such as
leaves.
Check that the water is at proper level, 2/3 up the Vortex skimmer
opening(s).
Inspect the filter cartridge(s) for dirt and debris.
Check for pump air lock.
Physical Specifications Size
JET VALVES ARE HARD TO OPERATE
Dimensions/mm 2134 x 1524
Valves and rotating jets that become hard to turn is an indication of sand, dirt
or too high calcium level in the water.
Height/mm 749
Corner Radius/mm 432
Seating Capacity/Positions 3/4
Remove components and rinse before damage occurs.
Weight Dry/Kgs. 186
Advise bathers to shower or use a foot bath before entering the spa. Failure to
use or maintain valves as directed may cause damage by introduction of foreign
materials such as dirt, sand and calcium that is not covered under the warranty.
Weight Full/Kgs. 810
Water Capacity/Litres 623
Total Therapy Jets 19
NO HEAT
Check temperature displayed in the LCD window for desired temperature setting.
Inspect the filter cartridge(s) for dirt and debris.
Check that the water is at proper level, 2/3 up the Vortex skimmer
opening(s).
Check HEAT MODE to be certain spa is not in SLEEP MODE or ECONOMY
MODE.
Lower ambient temperatures may result in heat loss.
NOTE: Do not expect instant hot water from the jets. It will take the heater 12-24
hours to heat the water to the temperature you desire.
Spirit Zone Control
ZONE 1A
Upper-, mid- and lower-back jets.**
ZONE 1B
Lower- body jets.**
*Items are optional. Check with dealer for
availability.
**HK™8 Neck Jets operate in every zone.
LIGHT DOES NOT WORK
Press the LIGHT pad on the control panel.
Reposition the light bulb in the socket. (See REPLACING LIGHT BULB.)
Replace the light bulb with similar component only.
OZONATOR BUILDUP
There can be a build up of nitrous compounds that typically gather at the ozone
outlet connection to the tubing after a six to 12 month period. If you see a
“gummy” build up at the point where the ozone tubing is connected to the ozone
generator, do the following:
Turn electrical power off.
Disconnect the tubing and clean it out using a Q-tip dipped in white vinegar.
Take care to avoid cracking or breakage when you remove the tubing from
the barbed fitting.
LCD DIAGNOSTIC MESSAGES
The advanced technology built into the spa allows it to perform a number of self-
diagnostic system checks and it can display a variety of messages in the LCD
window on the control panel.
OHH, HH: Over heat protection. If a malfunction occurs and the spa water
reaches 44°C, the system completely shuts down. In such a condition, DO NOT
ENTER THE WATER. Turn off all power to the spa. Remove spa cover and
allow water to cool. Once the heater has cooled, turn on power to the spa, then
reset by pushing any pad. If spa does not reset, shut off the power to the spa
and contact your authorized Marquis Spas® dealer for service. Several
conditions could lead to overheating, for example, low water level, shut-off
valves closed while heater is on, dirty filter, and restriction in the plumbing lines.
16
Page view 15