SUCTION GUARDS
The suction guard(s) in the footwell of your spa is an
opening through which the jet pump(s) draws water.
Suction fittings are equipped with a safety guard.
Suction through the fittings can be strong. The safety
guard(s) must remain in place and undamaged. A
fitting with a damaged guard(s) can be dangerous,
especially to small children or people with long hair.
Should any part of the body become drawn to a
fitting, turn the jet pump(s) off immediately. Long hair
should be restrained in a bathing cap, never allow it to
float freely in the spa. Replace any missing or dam-
aged suction guard(s).
NOTE: It is normal for the flow rates of the suction
fittings to vary from strong to barely noticeable.
ELECTRICAL REQUIREMENTS
It is the responsibility of the spa owner to ensure that
all electrical connections are made in accordance with
all electrical codes in effect at the time of installation.
240 Volt:
All connections must be made in accordance with
the wiring diagram found on the inside of the control
box cover. Connections must be made with copper
conductors only – do not use aluminum wiring with
this system. All conductors, circuit breakers, and/or
fuses must be sized in accordance to the total
amperage load as specified:
Permanently connected
Rated 240V, 60 Hz, 50A, three wires (#6
copper) plus ground (#8 AWG copper)
Fuse or circuit breaker size: 50 amp
When using a 30 amp breaker convert system
from 50 amps to 30 amps. Move the dip switch
A3 to the OFF position.
The heater will turn off when the pump(s) is on
high speed.
For units for use in other than single-family
dwellings, a clearly labeled emergency switch
shall be provided as part of the installation. The
switch shall be readily accessible to the occu-
pants and shall be installed adjacent to, within
sight of, and at least five feet (1.52 m) from the spa.
This equipment is designed to operate on 60Hz
alternating current only at a voltage of 240 (+ or -).
Units to be operated at 240V must have all connec-
tions made by a qualified electrician in accordance
with all electric codes in effect at the time of installa-
PAGE 13
installation instructions
Safety guard of
suction fitting must
remain in place.